For each size of SAE J514 JIC fittings, nine test assemblies in accordance with ISO 19879 shall be subjected to the proof test procedure specified in ISO 19879, prior to burst and cyclic endurance tests. They shall not leak at the respective proof pressures given in as follows:
Test pressures for steel and stainless steel 37° flared connections
Tube OD Working pressure b Test pressures Metric a Inch Proof Burst Cyclic endurance
mm in MPa (bar) c MPa (bar) MPa (bar) MPa (bar)
6 1/4 35 (350) 70 (700) 140 (1400) 46,6 (466)
8 5/16 35 (350) 70 (700) 140 (1400) 46,6 (466)
10 3/8 35 (350) 70 (700) 140 (1400) 46,6 (466)
12 1/2 31 (310) 62 (620) 124 (1240) 41,2 (412)
16 5/8 24 (240) 48 (480) 96 (960) 31,9 (319)
20 3/4 24 (240) 48 (480) 96 (960) 31,9 (319)
25 1 21 (210) 42 (420) 84 (840) 27,9 (279)
30 and 32 1 1/4 17 (170) 34 (340) 68 (680) 22,6 (226)
38 1 1/2 14 (140) 28 (280) 56 (560) 18,6 (186)
50 2 10,5 (105) 21 (210) 42 (420) 14 (140)
a Metric tubing shall be preferred.
b For working pressure applications higher than those given in Table 1, the manufacturer shall be consulted.
c 1 bar = 10 5 N/m 2 = 10 5 Pa = 0,1 MPa
Test pressures for copper alloy 37° ° flared connections
Tube OD Working pressure b Test pressures Metric a Inch Proof Burst Cyclic endurance
mm in MPa (bar) c MPa (bar) c MPa (bar) c MPa (bar) c
6 1/4 20 (200) 40 (400) 80 (800) 26,6 (266)
8 5/16 20 (200) 40 (400) 80 (800) 26,6 (266)
10 3/8 16 (160) 32 (320) 64 (640) 21,3 (213)
12 1/2 16 (160) 32 (320) 64 (640) 21,3 (213)
16 5/8 12,5 (125) 25 (250) 50 (500) 16,6 (166)
20 3/4 12,5 (125) 25 (250) 50 (500) 16,6 (166)
25 1 10 (100) 20 (200) 40 (400) 13,3 (133)
30 and 32 1 1/4 8 (80) 16 (160) 32 (320) 10,6 (106)
38 1 1/2 6,3 (63) 12,6 (126) 25,2 (252) 8,4 (84)
50 2 5 (50) 10 (100) 20 (200) 6,7 (67)
The pressure values for copper alloy connectors and tubes were produced using brass connectors with phosphorescent soft-annealed copper tubing.
a Metric tubing shall be preferred.
b For working pressure applications higher than those given in Table 1, the manufacturer shall be consulted.