SAE J514 JIC fittings specification for torque value is related to the burst test. Three of the test assemblies that had been subjected to the proof test in 15.1.1 shall be used for the burst test. The test shall be conducted in accordance with the burst test procedure specified in ISO 19879 and at the minimum torque values
Qualification test torque requirements
Tube OD Thread Torque a N⋅m Overtorque N⋅m mm 10 % 0 % +
6 7/16-20 UNF 15 24
8 1/2-20 UNF 19 31
10 9/16-18 UNF 24 42
12 3/4-16 UNF 49 80
16 7/8-14 UNF 77 114
20 1 1/16-12 UN 107 160
25 1 5/16-12 UN 147 214
30/32 1 5/8-12 UN 172 271
38 1 7/8-12 UN 215 339
50 2 1/2-12 UN 332 497
a These torque values are for qualification testing only and may differ from the
assembly torques supplied by the manufacturer.